Key Takeaways

  • A dedicated circuit for the charger, not a shared socket.
  • A suitable protection breaker (about 40 A for 7 kW) with RCD protection and proper earthing.
  • Check household load and panel capacity before installing.
  • An 11 kW charger needs a three-phase supply.

Before buying a charger, make sure your home is ready for it. The key requirements:

1. A dedicated circuit

A charger is a high continuous load for hours, so it needs its own circuit straight from the panel with a correctly sized cable, not a socket shared with other appliances.

2. Protection breaker, RCD and earthing

A breaker of about 40 A is typical for a 7 kW charger and 50-60 A for 11 kW, with RCD protection and proper earthing to protect people from leakage current.

3. Panel capacity and household load

If the panel is full or the household load is high, you may need a panel upgrade or a load increase request to the utility. We measure the actual load and explain your options.

4. Supply type

A single-phase supply usually handles a 7 kW charger. An 11 kW charger needs three-phase supply and a car that supports that rate.

Costs are broken down in the installation cost guide. To book: load check and panel upgrade in Khamis Mushait.

Frequently Asked Questions

Do I need a dedicated circuit for an EV charger?

Yes. A dedicated circuit with a protection breaker, RCD and earthing is recommended because a charger is a high, continuous load.

E
Written by

Electrical Team - 3mlak

Certified maintenance expert at 3mlak. Specialized in home maintenance solutions and energy efficiency.

Facing this problem?

Our team is ready to help solve the problem with warranty.

Professional Safety Technician
100% Safe

Your Safety First

We enforce strict safety protocols to protect your home and family during maintenance.

Health Check

Daily temperature checks for all staff.

Tool Sanitization

Full sterilization of tools before/after visits.

Shoe Covers

We wear protective covers to keep carpets clean.

Safe Materials

Cleaning agents & pesticides meet health specs.

Abu Saad

Abu Saad

General Supervisor

25 Years Experience
Expert Technician License
5.0/5.0
John Dela Cruz

John Dela Cruz

Lead Technician

12 Years Experience
HVAC MasterSafety Certified
5.0/5.0
Emergency RepairRequest Part